Low Power Factor

Low power factor is primarily caused by inductive loads such as motors and transformers, resulting in higher demand charges and power factor penalties. Static VAR Generators provide fast and continuous power factor correction, eliminating penalties and improving system efficiency.

Products and solutions refer to the tangible and intangible

Capacitor bank failures

Capacitor bank failures commonly occur due to harmonic distortion and over-voltage conditions, leading to frequent fuse blowing and downtime. Active Harmonic Filters eliminate harmonics, protecting capacitor banks and increasing their service life.

Products and solutions refer to the tangible and intangible

HIGH THD (%) – Current & Voltage Distortion

High total harmonic distortion (THD) is caused by non-linear loads such as VFDs, UPS systems, and SMPS-based equipment. High THD results in equipment overheating, losses, and malfunction. Active Harmonic Filters reduce THD to acceptable limits and ensure a clean power supply.

Products and solutions refer to the tangible and intangible

Harmonics from vfds

Data centres operate with a large number of servers, UPS systems, and SMPS-based loads that generate very high current harmonics and total harmonic distortion (THD). These harmonics cause overheating of transformers, cables, and panels, leading to energy losses and reduced system reliability. Active Harmonic Filters control harmonic distortion, improve power quality, and ensure high efficiency and maximum uptime for data centre operations.

Products and solutions refer to the tangible and intangible

High Neutral Current

Shopping malls use HVAC systems, escalators, elevators, lighting, and IT loads, many of which are driven by VFDs. These systems result in low power factor, harmonic distortion, and power factor penalties imposed by utilities. Static VAR Generators dynamically improve power factor, while Active Harmonic Filters reduce harmonics, helping malls lower electricity bills and maintain a reliable electrical system.

Products and solutions refer to the tangible and intangible

Transformer Overheating

Transformer overheating occurs due to harmonics, unbalanced loads, and excessive losses, reducing transformer life and reliability. A combination of Active Harmonic Filters and SVGs protects transformers by reducing thermal stress and improving load balance.

Products and solutions refer to the tangible and intangible

Power Factor Penalty

Power factor penalties are imposed by utilities when power factor falls below specified limits, increasing electricity costs. SVGs maintain power factor within required limits at all times, eliminating penalties and reducing energy bills.

Products and solutions refer to the tangible and intangible